EN 10025-6 S690Q, also written S690 Q, EN10025-6 S690Q and steel number 1.8931, is a weldable quenched and tempered structural steel, but weldability is a qualified-procedure issue, not an automatic property of the grade name. The notes below reuse the official welding and CEV wording already disclosed on EN 10025-6 S690Q, together with the official chemistry and strength tables.
EN 10025-6 S690Q Weldability — What Is Specified and What Is Practice
| Topic | Position used on this page |
|---|---|
| Official weldability statement | Weldable fine-grained steel, but a qualified WPS following EN 1011-2, low-hydrogen consumables and controlled heat input are required, as stated on EN 10025-6 S690Q |
| Cold-cracking risk | Increases with plate thickness, official-page wording |
| Carbon, heat analysis max | 0.20% |
| P / S, heat analysis max | 0.025% / 0.015% (QL uses lower official maxima) |
| CEV (EN 10025-6:2019, official wording) | Maxima rise with thickness, from 0.65 for plates up to 50 mm to 0.83 for the thickest plates. The actual CEV of each heat is printed on the mill certificate |
| Hot forming | Not recommended on the official page, because it can destroy quenched and tempered properties |
The official mechanical table on EN 10025-6 S690Q remains ReH 690 / 650 / 630 MPa and Rm 770–940 / 760–930 / 710–900 MPa in the 3–50 / >50–100 / >100–150 mm bands, with 14% minimum elongation and Charpy 30 J minimum at −20 °C, longitudinal. Welding procedure qualification must use the ordered thickness, CEV and toughness quality. EN 10025-6 S690QL is the −40 °C quality in the same strength class; it does not automatically satisfy a S690Q order, and S690Q does not automatically satisfy a QL order.
Frequently Asked Questions (FAQ)
Is EN 10025-6 S690Q weldable?
Yes, as a qualified fine-grained QT steel. The official EN 10025-6 S690Q page requires a WPS following EN 1011-2, low-hydrogen consumables and controlled heat input. The grade name alone does not pre-qualify a welding procedure.
What CEV should be used when welding EN 10025-6 S690Q?
Use the actual CEV printed on the mill certificate. Official wording for EN 10025-6:2019 is that the maxima rise from 0.65 for plates up to 50 mm to 0.83 for the thickest plates.
Can EN 10025-6 S690Q be hot formed after welding or instead of welding?
The official EN 10025-6 S690Q page states that hot forming is not recommended because it can destroy the quenched and tempered properties. Confirm any forming or post-weld heat treatment with the mill and the welding procedure.
For plate to EN 10025-6 S690Q (1.8931), Please contact Gangsteel with the designation, edition, delivery condition, dimensions, quantity and any supplementary requirements. Learn more about our carbon and high-strength steel plate at Gangsteel.