1.0570, also commonly written as DIN 1.0570, identifies the legacy DIN 17100 St52-3 steel grade. Common written forms of the grade name include St52-3, ST52-3 and St 52-3; St52-3N and ST52-3N make the normalized delivery condition explicit. These are written forms of the same DIN grade, not names of other standards.

The specified yield strength of 1.0570 is thickness-dependent. In DIN 17100:1980-01, Table 2, the minimum upper yield point ReH is 355 MPa at thickness up to 16 mm and falls in steps as the plate gets thicker. A single 355 MPa claim does not apply to every thickness.

1.0570 (DIN 17100 St52-3) Yield Strength by Thickness

Nominal plate thickness Upper yield point ReH min, MPa
<3 mm 355
3–16 mm 355
>16–40 mm 345
>40–63 mm 335
>63–80 mm 325
>80–100 mm 315
>100 mm By agreement

These minima are from Table 2 for St52-3. The N suffix in ST52-3N does not introduce a second yield table. For flat products of width ≥600 mm, tensile specimens, including the yield determination, are transverse to rolling; otherwise Table 2 specifies longitudinal specimens. Values above 100 mm must be agreed and must not be read from the thinner bands.

Tensile Strength and Elongation Alongside 1.0570 Yield

Yield is determined in the same tensile test that sets tensile strength and elongation. The Table 2 values below belong with the yield minima; they are not alternative strength grades.

Nominal plate thickness Tensile strength Rm, MPa Minimum transverse elongation, % (L₀ = 5d₀)
<3 mm 510–680 See the thin-product rules; the abbreviated elongation table starts at 3 mm
3–16 mm 490–630 20 (3–40 mm band)
>16–40 mm 490–630 20 (3–40 mm band)
>40–63 mm 490–630 19
>63–80 mm 490–630 18 (>63–100 mm band)
>80–100 mm 490–630 18 (>63–100 mm band)
>100 mm By agreement By agreement

The elongation entries are the Table 2 transverse values for proportional specimens, appropriate to flat products of width ≥600 mm. Longitudinal elongation and thin-product fixed-gauge-length requirements are different and are not copied here. Confirm specimen orientation and gauge length on the inspection document.

Impact Testing Is Separate from Yield

For the normalized N condition, Table 2 also specifies longitudinal ISO V-notch impact energy at −20 °C: 27 J at 10–63 mm and 23 J above 63–100 mm. Those results are not yield-strength values, and the test temperature is not a service-temperature rating. They apply to the N condition, relevant to ST52-3N plate, not as an unconditional claim for untreated delivery. Full impact rules, including the three-test average and subsize provisions, are given on the DIN 17100 St52-3 / ST52-3N product page.

Reading 1.0570 Yield on the Certificate and the Order

  • Check that the measured yield is at least the Table 2 minimum for the ordered thickness, not the 355 MPa value from a thinner band.
  • Record the delivery condition. N is the usual condition for St52-3 plate, but the certificate must show the actual route.
  • Do not treat a current 355 MPa EN grade as automatically satisfying a 1.0570 yield requirement at every thickness; compare the thickness band, tensile range and impact quality as well.
  • For thickness above 100 mm, the yield minimum is by agreement and must appear on the order before production.

Frequently Asked Questions (FAQ)

What is the yield strength of 1.0570 (DIN 17100 St52-3)?

For 1.0570 (DIN 17100 St52-3), the minimum upper yield point is 355 MPa at thickness up to 16 mm, then 345 MPa above 16–40 mm, 335 MPa above 40–63 mm, 325 MPa above 63–80 mm and 315 MPa above 80–100 mm. Above 100 mm the value is by agreement.

Is the yield strength of 1.0570 (DIN 17100 St52-3) always 355 MPa?

No. 355 MPa applies only up to 16 mm. Thicker 1.0570 (DIN 17100 St52-3) plate has lower specified minima. Quoting 355 MPa on an 80 mm plate is incorrect.

Does ST52-3N have a higher yield than 1.0570 (DIN 17100 St52-3)?

No. ST52-3N uses the same Table 2 yield minima as 1.0570 (DIN 17100 St52-3). N identifies normalized delivery; it does not raise the specified yield.

Is the yield of 1.0570 (DIN 17100 St52-3) the same as S355?

Up to 100 mm, EN 10025-2 S355 qualities use the same yield minima in the corresponding thickness bands as 1.0570 (DIN 17100 St52-3). The tensile range, impact quality and delivery condition still differ, so a matching yield class is not automatic substitution.

What tensile strength goes with the yield of 1.0570 (DIN 17100 St52-3)?

Tensile strength is 510–680 MPa below 3 mm and 490–630 MPa from 3–100 mm. Both the yield minimum and the tensile range must be met for the ordered thickness.

For plate to 1.0570 (DIN 17100 St52-3) or ST52-3N, please contact Gangsteel with the standard edition, grade, delivery condition, dimensions and quantity. Learn more about our structural and high-strength steel plate at Gangsteel.

1.0570 Yield Strength: DIN 17100 St52-3 Mechanical Properties