EN 10025-6 S550QL, also written S550 QL, EN10025-6 S550QL and steel number 1.8926, is a quenched and tempered structural steel with a guaranteed Charpy test at −40 °C. It is not a designated high-temperature pressure-vessel grade. EN 10025-6 does not publish elevated-temperature yield or allowable-stress tables for continuous service. This page therefore states the official room-temperature properties from EN 10025-6 S550QL and supplies only labeled conventional design notes so the temperature title is not left unanswered.
What EN 10025-6 S550QL Temperature Data Are Specified
| Topic | Position used on this page |
|---|---|
| Impact test temperature | −40 °C for the QL quality, with 30 J longitudinal minimum at that temperature on EN 10025-6 S550QL |
| Room-temperature ReH min, 3–50 mm | 550 MPa, falling to 530 MPa and 490 MPa in the official thicker bands |
| Room-temperature Rm, 3–50 mm | 640–820 MPa (590–770 MPa above 100–150 mm) |
| Colder or warmer qualities | EN 10025-6 S550QL1 is tested at −60 °C; EN 10025-6 S550Q is tested at −20 °C |
| High-temperature pressure-vessel service | Not the scope of EN 10025-6 |
A Charpy test temperature is not a service-temperature rating. The official EN 10025-6 S550QL page also states that hot forming is not recommended because it can destroy the quenched and tempered properties. Continuous operating temperatures approaching the original tempering range are a project-engineering question, not a hidden EN 10025-6 rating. This page does not invent a continuous-service temperature limit.
Conventional Notes When Elevated Temperature Is Discussed
| Context | Conventional compilation | Limitation |
|---|---|---|
| Ambient structural design (Eurocode 3) | Design yield fy / γ_M0 = 550, 530 or 490 MPa by official thickness band, with γ_M0 = 1.00 | Applies at the room-temperature material values; not a high-temperature allowable |
| Accidental fire design (EN 1993-1-2) | Carbon-steel reduction factors ky,θ remain 1.00 through 400 °C in Table 3.1, then fall (0.78 at 500 °C, 0.47 at 600 °C) | Fire-design reduction factors, not continuous operating-temperature allowables and not S550QL-specific test data |
| Modulus in fire design (EN 1993-1-2) | kE,θ = 1.00 at 20–100 °C, 0.90 at 200 °C, 0.80 at 300 °C, 0.70 at 400 °C, 0.60 at 500 °C | Same limitation: accidental fire design, not a service datasheet |
Frequently Asked Questions (FAQ)
What temperature is specified for EN 10025-6 S550QL?
The QL quality on EN 10025-6 S550QL is Charpy impact tested at −40 °C, with a 30 J longitudinal minimum at that temperature. That is a test temperature, not a rated minimum or maximum service temperature.
Is EN 10025-6 S550QL intended for high-temperature service?
Not as a pressure-vessel or boiler grade. EN 10025-6 S550QL is a quenched and tempered structural steel. High-temperature vessel steels must be specified by their own standard and grade name.
Does EN 10025-6 S550QL have published elevated-temperature yield values?
EN 10025-6 and the official EN 10025-6 S550QL page do not publish a continuous-service elevated-temperature yield or allowable-stress table. This page therefore does not invent one. The EN 1993-1-2 figures quoted above are conventional fire-design reduction factors only.
For plate to EN 10025-6 S550QL (1.8926), Please contact Gangsteel with the designation, edition, delivery condition, dimensions, quantity and any supplementary requirements. Learn more about our carbon and high-strength steel plate at Gangsteel.